WattNode Modbus

$309.00$434.00

Clear

Description

The WattNode® Modbus® is a kilowatt hour (kWh) energy and power meter that communicates on a EIA RS-485 network, measures 1, 2, or 3 phases with voltages from 120 to 600 volts Vac and currents from 5 to 6,000 amps in delta (phase to phase) and wye (phase to neutral) configurations.

linesheet reques-blue

Diagnostic LEDs

Diagnostic LEDs provide a per-phase indication of power (green flashing) and negative power (red flashing) to help troubleshoot connection problems, like reversed CTs, or excessive line voltage. The WattNode Modbus meter also has a red/yellow/green communication LED to indicate traffic, configuration problems, bus contention and other conditions. See the manual for full descriptions.

Measurements

  • True RMS Energy: Kilo-Watthours kWh (Phase A, B, C, and sum of all phases)
  • True RMS Power: Watts (Phase A, B, C, and sum of all phases)
  • Reactive Energy: kVAR-hours ((Phase A, B, C, and sum of all phases)
  • Reactive Power: VARs (Phase A, B, C, and sum of all phases)
  • Power Factor: (Phase A, B, C, and average of all phases)
  • RMS Voltage: (Phase A, B, C)
  • Computed RMS Current: (Phase A, B, C)
  • AC Line Frequency
  • Demand: (Sum, Minimum, Maximum)
  • Supports floating point and integer registers

WattNode Modbus—Features

Model Model Features
Meets ANSI C12.1 for use in revenue grade metering
CT rated amps value locked and cannot be changed to prevent tampering
Small form factor for easy installation inside most electrical panels, see a sample
WattNode Modbus Installation
Pluggable screw terminals for easy wiring
0.5% accuracy nominal (see Installation and Operation Manual for details)
True RMS power even with leading or lagging power factor and chopped or distorted waveforms
Measure variable speed drive pumps and motors
Safe CT’s (Current Transformers), output 333 mVac at rated current.

  • Split core CTs for quick installation
  • Solid core CTs are less expensive and prevent tampering
  • Bus Bar CTs for higher current applications (standard and custom sizes)
UL, cUL Listed – Designed and tested for safety and use throughout North America.
Assembled in USA, qualified under the Buy American provision in the American Recovery and Reinvestment Act of 2009 (ARRA).
Five year warranty

Safety Warning: Hazardous Voltages—Only qualified personnel or licensed electricians should install the WattNode meter and current transformers.

Modbus is a registered trademark of Schneider Electric USA, Inc.

WattNode® Modbus® – Manuals

Short and long versions of manuals are available and apply to both WattNode Modbus and WattNode Revenue for Modbus models.

Installation Guide

The short Installation Guide is intended for the electrician, contractor, or anyone installing network cabling.

Installation and Reference Manuals

The longer Installation and Reference Manual is  intended for programmers, designers, and installers.

See Also

WattNode® Modbus® – Specifications

Modbus Communication

  • Protocol: Modbus RTU (binary)
  • Baud Rates: 2,400, 4,800, 9,600,19,200, and 38,400 baud
  • Duplex: Half (two-wire plus common)
  • Parity (default): N81 (no parity, eight data bits, one stop bit)
  • Modbus Buffer: 256 bytes
  • Response Time (typical): 5 to 25 milliseconds

EIA RS-485 Interface

  • Driver Output Voltage (Open Circuit): ± V maximum
  • Driver Output Voltage (54Ω load): ± 1.5 V minimum
  • Driver Output Current (54Ω load): ± 60 mA typical
  • Driver Output Rise Time (54Ω || 50 pF load): 900 nS typical
  • Receiver Common-Mode Voltage Range: –7 to +12 Vdc maximum
  • Receiver Sensitivity: ±200 mV
  • Receiver Bus Load: 1/8 unit load

Electrical

  • Line powered
  • Operating Voltage Range: –20% to +15% of nominal
  • Power Line Frequency: 50 or 60 Hz
  • CT Input: 0.333 Vac nominal, 0 to 0.5 Vac operating, 3 Vac maximum

Measurement Configurations

Models available for:

  • Single phase: two or three wire
  • Three phase: four wire wye
  • Three phase: three wire delta
  • Three phase: four wire delta

Accuracy

WattNode Modbus

  • 0.5% nominal (see manual for details)

WattNode Revenue Modbus

  • 0.5% nominal (see manual for details)
  • Meets the accuracy requirements of the ANSI C12.1 standard when used with CCS CTs rated for IEEE C57.13 class 0.6 accuracy (see Revenue Grade CTs).
  • Models RWNC-3Y-208-MB, RWNC-3D-240-MB and RWNC-3Y-480-MB are certified by MET Laboratories to meet ANSI C12.1. MET Labs is a nationally recognized testing laboratory (NRTL).

Regulatory

  • FCC Class B, EN 55022 Class B
  • UL and cUL Listed (UL 61010-1), file number E312220
  • CE Mark and RoHS Declaration of Conformity
  • Immunity: EN 61326: 2002 (Industrial Locations)

Environmental

  • Operating Temperature: –30°C to +55°C (–22°F to +131°F)
  • Altitude: Up to 2000 m (6560 ft)
  • Operating Humidity: 5 to 90% relative humidity (RH) up to 40°C, decreasing linearly to 50% RH at 55°C.
  • Pollution: POLLUTION DEGREE 2 – Normally only non-conductive pollution; occasionally, a temporary conductivity caused by condensation must be expected.
  • Indoor Use: Suitable for indoor use.
  • Outdoor Use: Suitable for outdoor use when mounted inside an electrical enclosure (Hammond Mfg., Type EJ Series) that is rated NEMA 3R or 4.

Mechanical

WattNode-Case-Dimensions.png

Case Dimensions

(Click on the image for a larger view.)

  • Enclosure:
    • High impact, ABS plastic
    • Flame Resistance Rating: 94V-0, IEC FV-0
    • Size: 5.63 × 3.34 × 1.5 in. (143 × 85 × 38 mm)
    • Weight: 10.8 oz (305 g)
  • Connectors: Euroblock style pluggable screw terminal blocks
    • Green: 22 to 12 AWG (0.32 to 2.5 mm2), 600 V
    • Black: 22 to 12 AWG (0.32 to 2.5 mm2), 300 V

Modbus is a registered trademark of Modbus Organization, Inc.


Keywords: C12

WattNode® Modbus® – Models & Pricing

     
Model – MSRP Model – MSRP Vac Line to Neutral Vac Line to Line Electrical Service Types Neutral Required
WNC-3Y-208-MB
$309
RWNC-3Y-208-MB
$360
120 208-240 Single-Phase 120V with neutral
Single-Phase 3-Wire 120/240V
3-Phase 4-Wire Wye 120/208V
Yes
WNC-3Y-400-MB
$339
RWNC-3Y-400-MB
$398
230 400 Single-Phase 230V with neutral
3-Phase 4-Wire Wye 230/400V
Yes
WNC-3Y-480-MB
$339
RWNC-3Y-480-MB
$398
277 480 Single-Phase 277V with neutral
3-Phase 4-Wire Wye 277/480V
Yes
WNC-3Y-600-MB
$369
RWNC-3Y-600-MB
$434
347 600 Single-Phase 347V with neutral
3-Phase 4-Wire Wye 347/600V
Yes
WNC-3D-240-MB
$339
RWNC-3D-240-MB
$398
See below 208-240 Single-Phase 208V (No neutral)
Single-Phase 240V (No neutral)
Single-Phase 3-Wire 120/240V
3-Phase 3-Wire Delta 208V–240V (No neutral)
3-Phase 4-Wire Wye 120/208V
 
WNC-3D-400-MB
$369
RWNC-3D-400-MB
$434
See below 400 3-Phase 3-Wire Delta 400V (No neutral)
3-Phase 4-Wire Wye 230/400V
 
WNC-3D-480-MB
$369
RWNC-3D-480-MB
$434
See below 400-480 3-Phase 3-Wire Delta 480V (No neutral)
3-Phase 4-Wire Wye 277/480V
 
  • Voltage Ranges listed in table are -20% to +15% of nominal. For 3D-240 models, this is -20% of 208 Vac (166 Vac) to +15% of 240 Vac (276 Vac). Operating Frequencies: 50/60 Hz
  • Delta models, RWNC-3D-240-MB, RWNC-3D-400-MB, and RWNC-3D-480-MB, work either with or without a neutral connection, but require a line-to-line voltage connection for operating power.
  • Add 10% to the indicated price for any option or valid combination of options. For a list of available options see the Modbus Options tab.
  • Models RWNC-3Y-208-MB, RWNC-3D-240-MB and RWNC-3Y-480-MB are certified by MET Laboratories to meet ANSI C12.1. MET Labs is a nationally recognized testing laboratory (NRTL).

WattNode® Modbus® – Downloads

These downloads apply to the following two families of WattNode meters for the Modbus protocol:

  • WattNode Modbus
  • WattNode Revenue for Modbus

Datasheet, Manual, XIF File, and Application Notes

Updates

The WattNode Modbus production firmware version is periodically updated. The firmware cannot be field upgraded, so the WattNode meter must be returned to the factory for firmware updates. There is a nominal charge for firmware updates unless they are needed to fix a bug under warranty. Unless you are experiencing problems, there is generally no reason to update the firmware.

See WattNode Modbus Firmware Versions for the full list of versions.

Modbus is a registered trademark of Schneider Electric USA, Inc.

WattNode® Modbus – Options

The WattNode® Modbus® and WattNode Revenue Modbus meter is available with several factory options at an additional charge. See the WattNode Modbus manual (pdf) for more information and details about the registers mentioned below.

These options apply to the following two families of WattNode meters for the Modbus protocol:

  • WattNode Modbus
  • WattNode Revenue for Modbus

General Options

  • Option CT=xxx – Pre-assign xxx as the global CtAmps value.
    Except on Revenue models, this can be field configured or overridden using the CtAmps register.
    On WattNode Revenue models, Option CT will be factory-set to match the CTs specified when ordering the meter.
  • Option CT=xxx/yyy/zzz – Pre-assign xxx to CtAmpsA, yyy to CtAmpsB, and zzz to CtAmpsC.
    Except on Revenue models, these can be field configured or overridden using the CtAmpsA, CtAmpsB, and CtAmpsC registers.
  • Option FP – Adds fast update power registers with updates every 200 milliseconds to support utility feed-in limiting requirements for inverters.

Communication Options

  • Option EP – Factory configure the Modbus RS-485 communications to default to even parity (E81)
    This can be field configured using the ParityMode register if you have meters that were ordered without this option and you need even parity. This can be overridden or turned off in the field by changing the the ParityMode register.
  • Option 19K – Factory configure the RS-485 communications 19,200 baud.
    This can be changed in the field by switching the baud rate DIP switch, or by writing to the Baud register. If you write “0” to the BaudRate register, then the DIP switch setting will control the baud rate.
  • Option 38K – Factory configure the RS-485 communications to 38,400 baud. Position 8 of the DIP switch will be ignored.
    This can be changed in the field by writing a new value to the BaudRate register. If you write “0” to the BaudRate register, then the DIP switch setting will control the baud rate.
  • Option TCP-RTU – Configure the communications to the Modbus TCP-RTU protocol option for use with RS-485 to Ethernet converters (serial device adapters).
    This can be field configured or disabled with the ModbusMode register.
  • Option AD – Factory configure the Modbus address.
    This can be changed in the field by by writing a new address to the Address register. If you write 0 (zero) to the Address register, then the DIP switch setting will specify the Modbus address.

Note: All WattNode Modbus meters can have their communication settings restored to factory shipped values by setting all DIP switch positions to “0” for ten seconds. If an communication option has been ordered, the meter will restore to include the settings from any options.

X Terminal Options

These options all utilize the X (auxiliary) terminal on the “MODBUS” connector:

  • Option X5 – Provides 5 Vdc at up to 60 milliamps between the C (common) and X (5V) terminals.
  • Option IO – Provides a digital input (level sensing and pulse counting) or output (for load shedding and other applications) on the X terminal.
  • Option SSR – Provides a solid-state relay (contact closure) output between the X and C terminals for load shedding and other applications.

Special Options

Contact the factory about the following special options:

  • Option 232 – Provide RS-232 I/O in place of RS-485.
  • Option TTL – Provide 5V TTL UART I/O in place of RS-485.

See Also